1000VA 110V-60Hz UPS-Online MAXX-UPS10ONK 110CE For Marine


Ref: IMPA Code – 

Capacity Available – 1000VA/900W

Compact size

Easy to install and operate

Cold start function

Modem/LAN internet protection

AVR boost and buck

Compare

Features:

  • Rack/Tower convertible design
  • Online double conversion with full digital control
  • Wide input voltage range: 110~300Vac
  • High input power factor of 0.99 with Power Factor Correction (PFC)
  • Selectable output voltages: 208V, 220V, 230V, and 240V
  • Smart charger design for enhanced battery performance
  • Maximum charging current of 12A for extended runtime units
  • Emergency power off (EPO) function
  • Eco mode for energy savings
  • Generator compatibility
  • Hot-Swappable battery design
  • Cold start capability
  • Intelligent fan speed control
  • User-friendly LCD interface
  • VMultiple communication interface: RS232 (USB/EPO/Relay card /SNMP card optional)
  • Multiple protection functions: short-circuit, overload, overheat, battery overcharge and over-discharge, output low voltage and fan fault alarm

 

Categories: , ,

Technical Specifications

Model Number MAXX-UPS10ONK 220CE
Capacity 1000VA / 900W
Input
Nominal Voltage 100/110/115/120/125Vac
Input Voltage Range 110 ~ 300Vac (176 ~ 264Vac at 100% load)
Power Factor ≥0.99
Frequency
Frequency Range 40 ~ 70Hz (50/60Hz Auto Detection)
Output
Output Voltage 208/220/230/240Vac
Voltage Regulation ±1%
Power Factor 0.9
Output Frequency – Line Mode 46 ~ 54Hz or 56 ~ 64Hz
Output Frequency – Battery Mode (50/60±0.1%) Hz
Crest Factor 3:1
Total Harmonic Distortion (THDv) ≤3% Linear Load
≤5% Non-Linear Load
Transfer Time – AC to Battery 0ms
Transfer Time – Inverter to Bypass 4ms (Typical)
Output Waveform Pure Sine Wave
Efficiency
AC Mode 88%
Battery Mode 85%
Battery
Number of Batteries 2 ~ 3
Capacity (Standard Unit) 9Ah/12V (7Ah/12V optional)
Typical Charging Time 4 hours (up to 90% capacity)
Charging Voltage 27.4Vdc ±1%, 41.1Vdc ±1%
Charging Current (Max.) 6A / 12A
Indicators
LED Display Line Mode, Battery Mode, ECO Mode, Bypass Mode, Low Battery, Overload, UPS Failure
LCD Display Input Voltage, Input Frequency, Output Voltage, Output Frequency, % Load, Battery Voltage, Internal Temperature, Remaining Backup Time
Alarm
Battery Mode Beep every 4 seconds
Low Battery Beep every second
Overload Two beeps per second
Failure Continuous beep
Environment
Operating Temperature 0°C ~ 40°C
Storage Temperature -25°C ~ 55°C
Humidity Range 20~95% RH @ 0°C ~ 40°C (non-condensing)
Altitude <1500m, capacity adjustment required above 1500m
Noise Level <50dB at 1 meter
Shipping Details
Product Dimensions 191 x 460 x 337 mm
Box Dimensions 280 x 560 x 450 mm
Net Weight 19.5 kg
Gross Weight 21 kg
Standards
Safety IEC/EN 62040-1, IEC/EN 62477-1
EMC IEC/EN 62040-2 (IEC 61000 series)

Select at least 2 products