110V Offline UPS – Uninterrupted Power Supply MAXX – 110V For Marine


Ref: IMPA Code – 

Capacity Available – 600VA

Compact size

Easy to install and operate

Cold start function

Modem/LAN internet protection

AVR boost and buck

Compare

Features:

  • High power density
  • Online double conversion with full digital control
  • Wide input voltage range: 81~145Vac
  • High input power factor of 0.99 with Power Factor Correction (PFC)
  • Selectable output voltages: 110v & 120v
  • Smart charger design for enhanced battery performance
  • Maximum charging current of 12A for extended runtime units
  • Emergency power off (EPO) function
  • Eco mode for energy savings
  • Generator compatibility
  • Cold start capability
  • Intelligent fan speed control
  • Optional load segment setting
  • User-friendly LCD interface
  • Various communication options including RS232, USB, EPO, relay card, and optional SNMP card
  • Multiple protection features including short-circuit protection, overload protection, overheating protection, battery overcharge/overdischarge protection, low output voltage protection, and fan fault alarms.

 

SKU: 5487FB8/22-2-1-1-1-1-2-3-1-1-2-1-2-1-2-1-1-1-2-1-1-2-1-1-2-1-2-2-2 Categories: , ,
Brands

MAXX

Technical Specifications

MODEL MAXX-UPS6 OFK110
Capacity 600VA/360W
INPUT
Voltage 110/120VAC
Voltage Range 81~145Vac
Frequency Range 60/50Hz (Auto sensing)
OUTPUT
AC Voltage Regulation (Batt. Mode) ±10%
Frequency Range (Batt. Mode) 60/50Hz ±1 Hz
Transfer Time Typical 2-6ms, 10ms Max.
Waveform (Batt. Mode) Simulated Sinewave
BATTERY
Battery Voltage 12Vdc
Battery Type & Number 12 V/7Ah×1 12 V/9 Ah×1
Typical Recharge Time 4~6 hours to recover to 90% capacity
INDICATORS
LED Display(LED version) AC Mode, Battery Mode, Overload, Fault
LCD Display(LCD version) AC Mode, Battery Mode, Load Level, Battery Level, Input Voltage, Output Voltage, Overload, Fault, and Battery Low
PROTECTION
Full Protection Short circuit, Overload, Overcharge and overdischarge protection
ALARM
Battery mode Sounding every 10 seconds
Low Battery Sounding every second
Overload Sounding every 0.5 seconds
Battery Replacement Alarm Sounding every 2 seconds
Fault Continuously sounding
MANAGEMENT
Communication port USB or RS232(Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7, Linux, Unix, and MAC)
OPERATING ENVIRONMENT
Humidity 0-90 % RH @ 0- 40°C (Non-condensing)
Noise Level  Less than 45dB
Shipping Details
Approx. Dimension (D×W×H) 298×101×142mm
Approx. Net Weight Approx. 4.3kg Approx. 4.9kg
Safety IEC/EN 62040-1; IEC/EN 60950-1
EMC IEC/EN 62040-2; IEC 61000-4-2; IEC 61000-4-3; IEC 61000-4-4; IEC 61000-4-5; IEC 61000-4-6; IEC 61000-4-8
Performance IEC/EN 62040-3

You cannot copy content of this page