Features:

  • High power density
  • Online double conversion with full digital control
  • Wide input voltage range: 110~300Vac
  • High input power factor of 0.99 with Power Factor Correction (PFC)
  • Selectable output voltages: 208V, 220V, 230V, and 240V
  • Smart charger design for enhanced battery performance
  • Maximum charging current of 12A for extended runtime units
  • Emergency power off (EPO) function
  • Eco mode for energy savings
  • Generator compatibility
  • Cold start capability
  • Intelligent fan speed control
  • User-friendly LCD interface
  • VMultiple communication interface: RS232 (USB/EPO/Relay card /SNMP card optional)
  • Multiple protection functions: short-circuit, overload, overheat, battery overcharge and over-discharge, output low voltage and fan fault alarm

 

SKU: 5487FB8/22-2-1-1-1-1-2-3-1-1-2-1-2-1-2-1-1-1-2-1-1-2-1-1-2-1-2-2-1 Categories: , ,
Brands

MAXX

Technical Specifications

Model Number MAXX-UPS30ONK 220CE
Capacity 3000VA / 2700W
Input
Nominal Voltage 208/220/230/240Vac
Input Voltage Range 110 ~ 300Vac (176 ~ 264Vac @ 100% load)
Power Factor ≥0.99
Frequency
Frequency Range 40 ~ 70Hz (Auto-detection 50/60Hz)
Output
Output Voltage 208/220/230/240Vac
Voltage Regulation ±1%
Power Factor 0.9
Output Frequency Line Mode 46 ~ 54Hz or 56 ~ 64Hz
Battery Mode (50/60±0.1%) Hz
Crest Factor 3:1
Total Harmonic Distortion (THDv) ≤3% Linear Load
≤5% Non-Linear Load
Transfer Time From AC to Battery Mode 0ms
From Inverter to Bypass 4ms (Typical)
Output Waveform Pure Sine Wave
Efficiency
AC Mode 91%
Battery Mode 88%
Battery
Number of Batteries 6-8
Capacity (Standard Unit) 9Ah/12V (7Ah/12V Optional)
Typical Charge Time 4 hours (up to 90% of total capacity)
Charging Voltage 82.2Vdc±1% / 109.6Vdc±1%
Charging Current (Max.) 6A/1A
Indicators
LED Display Line Mode, Battery Mode, ECO Mode, Bypass Mode, Low Battery, Overload, and UPS Fault
LCD Display Input Voltage, Input Frequency, Output Voltage, Output Frequency, Load %, Battery Voltage, Internal Temperature, and Remaining Backup Time
Alarm
Battery Mode Beep every 4 seconds
Low Battery Beep every second
Overload Two beeps per second
Fault Continuous beep
Environmental Conditions
Operating Temperature 0°C ~ 40°C
Storage Temperature -25°C ~ 55°C
Humidity Range 20~95% RH @ 0°C ~ 40°C (non-condensing)
Altitude <1500m, capacity derating required above 1500m
Noise Level <50dB at 1 meter
Shipping Information
Dimensions (W x D x H) Product
Box
Weight Net 29.5 kg
Gross
Standards
Safety IEC/EN 62040-1, IEC/EN 62477-1
EMC IEC/EN 62040-2 (IEC 61000-4-2, IEC 61000-4-3, IEC 61000-4-4, IEC 61000-4-5, IEC 61000-4-6, IEC 61000-4-8, IEC 61000-4-11, IEC 61000-2-2)