3000VA 110V-60Hz UPS-Online MAXX-UPS30ONK 110CE For Marine


Ref: IMPA Code – 

Capacity Available – 3000VA/2700W

Compact size

Easy to install and operate

Cold start function

Modem/LAN internet protection

AVR boost and buck

Compare

Features:

  • Rack/Tower convertible design
  • Online double conversion with full digital control
  • Wide input voltage range: 110~300Vac
  • High input power factor of 0.99 with Power Factor Correction (PFC)
  • Selectable output voltages: 208V, 220V, 230V, and 240V
  • Smart charger design for enhanced battery performance
  • Maximum charging current of 12A for extended runtime units
  • Emergency power off (EPO) function
  • Eco mode for energy savings
  • Generator compatibility
  • Hot-Swappable battery design
  • Cold start capability
  • Intelligent fan speed control
  • User-friendly LCD interface
  • VMultiple communication interface: RS232 (USB/EPO/Relay card /SNMP card optional)
  • Multiple protection functions: short-circuit, overload, overheat, battery overcharge and over-discharge, output low voltage and fan fault alarm

 

SKU: 5487FB8/22-2-1-1-1-1-2-3-1-1-2-1-2-1-2-1-1-1-2-1-1-2-1-1-2-1-2-2-1-1 Categories: , ,
Brands

MAXX

Technical Specifications

Model Number MAXX-UPS30ONK 220CE
Capacity 3000VA / 2700W
Input
Nominal Voltage 100/110/115/120/125 Vac
Input Voltage Range 110 ~ 300 Vac (176 ~ 264 Vac @ 100% load)
Power Factor ≥0.99
Frequency
Frequency Range 40 ~ 70 Hz (auto detection 50/60 Hz)
Output
Output Voltage 208/220/230/240 Vac
Voltage Regulation ±1%
Power Factor 0.9
Output Frequency Line Mode 46 ~ 54 Hz or 56 ~ 64 Hz
Battery Mode (50/60 ±0.1%) Hz
Crest Factor 3:1
Total Harmonic Distortion (THDv) ≤3% Linear Load / ≤5% Non-Linear Load
Transfer Time AC to Battery Mode 0 ms
Inverter to Bypass 4 ms (Typical)
Output Waveform Pure Sine Wave
Efficiency
AC Mode 91%
Battery Mode 88%
Battery
Number of Batteries 6 ~ 8
Capacity (Standard Unit) 9Ah/12V (7Ah/12V Optional)
Typical Charge Time 4 hours (up to 90% capacity)
Charge Voltage 82.2 Vdc ±1%, 109.6 Vdc ±1%
Charge Current (Max.) 6A / 12A
Indicators
LED Display Line mode, battery mode, ECO mode, bypass mode, low battery, overload, UPS failure
LCD Display Input voltage, input frequency, output voltage, output frequency, load percentage, battery voltage, internal temperature, remaining backup time
Alarm
Battery Mode One beep every 4 seconds
Low Battery One beep per second
Overload Two beeps per second
Failure Continuous beep
Environmental Conditions
Operating Temperature 0°C ~ 40°C
Storage Temperature −25°C ~ 55°C
Humidity Range 20%~95% RH @ 0°C ~ 40°C (no condensation)
Altitude <1500 m, capacity reduction required above 1500 m
Noise Level <50 dB at 1 meter distance
Shipping Information
Dimensions (W x D x H) Product 191 x 460 x 337 mm
Box 280 x 560 x 450 mm
Weight Net 19.5 Kg
Gross 21 Kg
Regulations
Safety IEC/EN 62040-1, IEC/EN 62477-1
EMC IEC/EN 62040-2 (includes IEC 61000-4-2, -3, -4, -5, -6, -8, -11, IEC 61000-2-2)

Select at least 2 products
to compare